A junction box is the proper way of “splicing” wire without any concern for safety. New wiring can be run from the junction box to the outlets that require upgrading. The equipment bonding conductors in the junction box must be properly connected to an equipment grounding conductor sized for the circuit that terminates on a grounding busbar in a subpanel, or the neutral busbar at the main panel to ensure that this method is code compliant. Install a junction box close to the main panel (the junction box must be accessible at all times).This means that all new outlets will require running new wire from the outlet back to the main panel. Install three-slot outlets and wire them so that they are correctly grounded.Upgrading the electrical system can be accomplished in one of the following ways: How can ungrounded outlets be upgraded safely? By rule of thumb, if a building still uses knob-and-tube wiring, it is likely that any three-slot outlets are ungrounded. Replacing a two-slot outlet with a three-slot outlet without rewiring the electrical system may serve as a seemingly proper outlet for three-pronged appliances however, this “upgrade” is potentially more dangerous because the outlet will appear to be grounded and future homeowners might never be aware that their system is not grounded. A short circuit in the receptacle wiring, combined with ungrounded outlets typically found in older houses is a recipe for potential fire and injury.Ĭan a two-slot outlet simply be replaced with a three-slot receptacle? Watch out for deterioration of wires and their protective insulation. This is why overloading outlets by plugging in too many appliances is a bad idea…and it’s an even bigger risk if you overload a ungrounded outlet. If more energy than that runs through the wire, the risk of a fault increases. Most residential electrical outlets are connected to circuits of 120 volts. Since 1962, the National Electrical Code has required three-prong outlets for all new homes. If the home was built before 1960, it likely has as least some two-prong ungrounded outlets, although some may have been upgraded to grounded outlets. The ground wire provides an alternate path for electricity that may stray from an appliance or product to make its way safely back to the breaker or fuse box and exit the building into the main ground connection. Prior to that time, most wiring was just two wires (hot and neutral). Since the early 1960s, most electrical codes have required a ground wire to be run to all outlets and appliances. Modern, grounded 120-volt receptacles, also referred to as outlets, in North America have a small, round ground slot centered below two vertical hot and neutral slots, and it provides an alternate path for electricity that may stray from the appliance. What is the difference between the two types of outlets?
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |